INVERX Vertical

Product Pictures of Fairland
Product Pictures of Fairland
Product Pictures of Fairland

Powered by  

Features:
TurboSilence Inverter Technology
• Averagely more than 15 Times Quieter
• Turbo/ Smart/ Silence Mode Selection
• 3 Times Energy Saving, COP up to 16
• Built-in Wi-Fi for Free
• Operating Air Temperature -15℃~43℃
 
Applications:
• Pool Size Range 15m³~160m³
• Indoor and Outdoor Pools




  • Details
  • Tech info of R32
  • Tech info of R410A
  • Download

• Super energy-saving: Half running cost

The new TurboSilence inverter Technology is optimized on the basis of Full-inverter Technology, the whole control system and corresponding components are upgraded, it can instantly increase heating capacity by 20%, but with silent running.

INVERX VERTICAL TurboSilence inverter pool heat pump running status under different mode - fairland pool heating solution

• Averagely more than 15 Times Quieter

All INVERX models are with twin-rotary compressor to minimize vibration.
Running by AVERAGE 50% capacity to maintain pool temperature for whole swimming season, which means 15 times quieter swimming environment & friendly neighborhood.
INVERX VERTICAL Turbo Silence averagely more than 10 times quieter - fairland pool heating solution

• 3 Times Energy Saving

Average COP 11.6 at 50% capacity, COP up to 16.3 (Air 26°C/Water 26°C/Humidity 80%)
 

• Other Advantages

Intelligent Touch Controller
INVERX VERTICAL intelligent touch controller - fairland pool heating solution

• Patented Design

Unique air flow technology leads to most silent ventilation.
TurboSilence INVERX VERTICAL inverter pool heat pump PATENTED DESIGN - fairland pool heating solution
 

SPECIFICATIONS OF INVERX VERTICAL TURBOSILENCE FULL-INVERTER POOL HEAT PUMP
Model IXCR26V IXCR36V IXCR46V IXCR56V IXCR66V IXCR80V IXCR80VT IXCR110VT
Advised pool volume (m3) 20~40 25~50 30~60 40~75 50~100 65~120 65~120 90~160
Operating air temperature (℃) -15~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW) in Smart mode 8.8 11.3 14.5 18.0 23.0 27.5 27.5 35.0
Heating capacity (kW) in Turbo mode 10.5 13.5 17.5 21.5 27.0 32.0 32.0 40.0
COP in Smart mode 7.8 7.9 8.0 7.5 8.0 7.6 7.6 7.5
COP 15.4~7.1 15.6~7.0 16.1~6.7 16.0~6.5 15.3~7.1 16.3~6.5 16.3~6.5 16.0~6.6
COP at 50% capacity 11.5 11.8 12.1 12.0 11.6 11.5 11.5 11.4
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW) in Smart mode 6.3 7.5 10.0 12.0 15.0 18.5 18.5 24.5
Heating capacity (kW) in Turbo mode 7.5 9.0 12.0 14.5 18.0 22.0 22.0 28.5
COP in Smart mode 5.1 5.1 5.0 5.0 5.1 5.5 5.5 5.3
COP 7.2~4.5 7.5~4.6 8.0~4.6 7.6~4.5 7.5~4.9 8.0~5.0 8.0~5.0 7.9~4.8
COP at 50% capacity 6.6 6.7 6.9 7.0 6.5 7.0 7.0 6.9
 
Heat exchanger Spiral titanium tube in PVC
Casing Aluminum-alloy Casing
Power supply 230V/1 Ph/50Hz 400V/3 Ph/50Hz
Rated input power at air 15°C (kW) 0.17~1.66 0.21~1.95 0.26~2.51 0.33~3.08 0.42~3.67 0.46~4.4 0.46~4.4 0.60~5.94
Rated input current at air 15°C (A) 0.74~7.21 0.91~8.48 1.14~10.9 1.43~13.4 1.82~15.9 2.01~19.1 0.66~6.35 0.87~8.57
Advised water flux (m³/h) 2~4 3~4 4~6 6.5~8.5 8~10 10~12 10~12 12~18
Water pipe in-out size (mm) 50

←Please drag to see more on small size devices→